×
×
×
Same day despatch

Got a question? Speak to our industry experts on 01473 461800

LuciPac A3 Surface Swabs for Lumitester A3 Smart (Box of 100)

Test Kit to monitor surface hygiene and cleaning effectiveness. Pack of 100 swabs measuring ATP, ADP and AMP.

Use only with the VLTA-01 Lumintester A3 SMART. 

A3 Technology detects not only ATP, but also the lower-energy molecules ADP and AMP. Consequently, it offers you far greater visibility and sensitivity than conventional ATP tests.

You will find more information in the Product Description below. Alternatively, you can click here to discuss a trial or trade-in with our team.

Video Tutorial: How to set up and use the A3 System
Code: VLTA-10
£259.82Order more and save!See pricing table below.

81 Available


Code: VLTA-10
Availability 81
£259.82Order more and save!See pricing table below.

Add to Favourites
Quantity Breaks (per unit)
1 to 4 £259.82
5 to 9 £246.83
10 to 14 £233.84
15 to 19 £227.34
20 + £207.86
For bulk quantities and scheduled deliveries, please contact our team.

Ultra-sensitive swab kit for the cleaning validation of surfaces. The LuciPac A3 Surface Swab Kit, in conjunction with Lumitester A3 Smart, detects all organic residues and microorganisms on surfaces and determines the cleanliness level. The system enables hygiene monitoring within seconds, followed directly after cleaning and disinfection steps. A3 technology detects not only ATP (adenosine triphosphate), but also the lower-energy molecules, ADP (adenosine diphosphate) and AMP (adenosine monophosphate). 

This represents a technological advancement over conventional ATP tests, as it significantly increases reading sensitivity. This is particularly important when dealing with heated and processed foods, as ATP is degraded to ADP and AMP during these processes and very difficult to detect with conventional ATP tests. 

Swab Storage Conditions

The LuciPac A3 Swabs should be stored at 2-8°C and should never be frozen. Under these conditions, they should be suitable for use until the expiry date on the box. We endeavour to supply the swabs with an expiry date of 12 months minimum. Alternatively, if you choose to store the swabs at 25°C, they will last 14 days unopened, and if you store them at 30°C, they will last five days unopened.

For optimal accuracy, A3 surface swabs should be used at room temperature (approximately 20–25 °C). If the swabs have been stored in refrigeration, they should be removed and allowed to warm up for around 10–20 minutes before use, as using them straight from the fridge may lead to lower or inaccurate readings. 

To support ease of use, A3 swabs can also be stored at ambient temperature (unopened) for up to two weeks, allowing users to keep a ready-to-use supply without the need to wait for warming before each test.

Working closely with a team of microbiologists, Klipspringer provides ongoing support for your A3 system. This involves helping you to choose the right number of swabs for each order and giving you the option of staggering your deliveries to secure swabs with the optimum lifespan.

Certification

The Kikkoman A3 Meter has been evaluated by the AOAC® Performance Tested Methods℠ Program and was found to perform to the manufacturer’s specifications. The two laboratories that independently carried out this testing were the NSF International and Q Laboratories. Access the certification that accompanies this system.

The Kikkoman A3 System - Software

Download the PC Software (OS: Windows 7 or 10)

You can also download the app to your Smartphone or Tablet:

 

A3 Technology and Industry Applications


The A3 System and Allergen Management

As with conventional ATP tests, the A3 System can NOT be used for the direct detection of allergens. However, due to its ability to detect all forms of organic residue, the Kikkoman A3 System could support your allergen management program. The reason for this is fairly simple: Proper Cleaning = Reduced Risk of Allergen Cross-Contact.

Learn more about the A3 System and Allergen Management

Packaging inc.100 swab sticks (5 x 20 each) for 100 determinations.Incubation time 10 sec
Storage Conditions2-8°C (Do not freeze)Storage Conditions at 25°C14 days (Unopened)
Evaluation BioluminescenceStorage Conditions at 30°C5 days (Unopened)

White Paper: Hygiene Verification - Analysing an alternative approach to ATP tests

  • Examine an emerging testing method that offers an alternative to traditional ATP assays
  • Comparative research from leading manufacturer
  • Improved hygienic design
Download resource here
How thorough is your cleaning verification process? 

In this webinar, Klipspringer Director, Alex Carlyon, is joined by McCain Foods Hygiene Manager, Nigel Church, and Cleaning Verification Specialist, Stephan Speidel, to review the new ‘A3’ cleaning verification technology


.