A3 Technology detects not only ATP, but also the lower-energy molecules ADP and AMP. Consequently, it offers you far greater visibility and sensitivity than conventional ATP tests.
ATP testing is a traditional method for ascertaining how well a surface has been cleaned and whether or not any organic residue remains. However, ATP is an unstable molecule that often degrades to ADP and AMP. When this happens, it becomes undetectable to a traditional ATP test.
In contrast, the A3 Kikkoman Lumitester is able to detect all forms of organic residue: ATP, ADP, and AMP. It offers unmatched sensitivity, allowing your team to detect residues that were previously overlooked.
Thanks to the system's Bluetooth compatibility, you can wirelessly transfer the results of your A3 test to your device (e.g. mobile, tablet, computer). There is also the option to use a cable. Alternatively, you can store and present your data via the cloud-based app.
The Kikkoman A3 Meter was awarded the Invention Implementation Achievement Award at the 2024 National Commendation of Invention hosted by the Japan Institute of Invention and Innovation.
Find out more about the A3 System
Learn more about the difference between ATP and A3 Testing
Benefits
- Lightweight and easy-to-use.
- Highly sensitive, precise measurement of ATP, ADP and AMP, giving far superior sensitivity than conventional ATP meters.
- Auto-calibration.
- Automatic Temperature Compensation (ATC).
- Set your own limits for pass/fail results.
- Bluetooth connection to app for storage of measurement results in the Cloud, allowing you to access the results from anywhere.
- Data visualisation in the app makes the measurement results easy to see and analyse in detail.
- Free Technical Support Available.
- 12 month warranty.
- Next day delivery for all swabs meaning there is no need to keep stock of swabs on site.
Swab Storage Conditions
The LuciPac A3 Swabs should be stored at 2-8°C and should never be frozen. Under these conditions, they should be suitable for use until the expiry date on the box. We endeavour to supply the swabs with an expiry date of 12 months minimum. Alternatively, if you choose to store the swabs at 25°C, they will last 14 days unopened, and if you store them at 30°C, they will last five days unopened.
For optimal accuracy, A3 surface swabs should be used at room temperature (approximately 20–25 °C). If the swabs have been stored in refrigeration, they should be removed and allowed to warm up for around 10–20 minutes before use, as using them straight from the fridge may lead to lower or inaccurate readings.
To support ease of use, A3 swabs can also be stored at ambient temperature (unopened) for up to two weeks, allowing users to keep a ready-to-use supply without the need to wait for warming before each test.
Working closely with a team of microbiologists, Klipspringer provides ongoing support for your A3 system. This involves helping you to choose the right number of swabs for each order and giving you the option of staggering your deliveries to secure swabs with the optimum lifespan.
Certification
The Kikkoman A3 Meter has been evaluated by the AOAC® Performance Tested Methods℠ Program and was found to perform to the manufacturer’s specifications. The two laboratories that independently carried out this testing were the NSF International and Q Laboratories. Access the certification that accompanies this system.
The Kikkoman A3 System - Software
Download the PC Software (OS: Windows 7 or 10)You can also download the app to your Smartphone or Tablet:
A3 Technology and Industry Applications
-
Learn more about the A3 System and Brewing
-
Discover more about A3 Technology and Fish, Seafood, and Fish Processing
-
Learn more about the role of A3 Technology in Meat Processing
- Discover more about the A3 System, Milk and Dairy Products
The A3 System and Allergen Management
As with conventional ATP tests, the A3 System can NOT be used for the direct detection of allergens. However, due to its ability to detect all forms of organic residue, the Kikkoman A3 System could support your allergen management program. The reason for this is fairly simple: Proper Cleaning = Reduced Risk of Allergen Cross-Contact.
| Temperature range | 5 - 40°C | Weight | 255g |
|---|---|---|---|
| Dimensions (mm) | 65 x 176 x 40mm | Software | Lumitester App |
| Power supply | 2 alkaline batteries (AA) | Unit of measurement | RLU |
| Data memory | 2000 Analyses | Incubation time | 10 sec |
| Connectivity | USB, Bluetooth LE (Ver4.1) | Evaluation | Bioluminescence |
AOAC Performance Certification
Referential Benchmarks.
Standard ATP Comparison
The A3 system is widely used across food and beverage manufacturing, including:
- Meat and poultry processing – cooked and processed meats, as well as broken down ATP post-cleaning in raw meat environments
- Ready-to-eat and cooked products – high-care, multi-ingredient, allergen and processed food environments
- Dairy-based products – cheese, yoghurts, pasteurised and fermented products
- Bakeries and confectionery – multi-ingredient, multi-allergen, fine dry residues and potential airborne cross-contamination
- Beverage production – yeast interference, multi-ingredient production, spills and cross-contamination risks
White Paper: Hygiene Verification - Analysing an alternative approach to ATP tests
- Examine an emerging testing method that offers an alternative to traditional ATP assays
- Comparative research from leading manufacturer
- Improved hygienic design